The
HygroPalm firmware version 4.1b or higher is designed for use with the
ROTRONIC
HW4 software.
HW4 is compatible with several other
ROTRONIC products.
HW4 is available in the following versions:
HW4 Professional with OPC Server: this version includes all features of
HW4 Professional while also providing OPC tags that can be enabled for each individual device communicating
with
HW4.
This allows exporting and integrating the
HW4 data with with practically any OPC client (requires configuration / programming of the OPC client by the user).
HW4 Validated : this version offers the same functionality as
HW4 Professional with OPC server.
Additionally, the “HW4 e-compliance Package” is available.
This extensive collection of documents (including template of qualification documents) is designed to support the “regulated user” by qualifying/validating
HW4-based solutions.
The most current validated release of HW4 is v 1.2.1. Release 1.2.2 will be validated during the second half of 2006.
HW4 Professional Trial Version: this is a fully functional version of
HW4 Professional, including the OPC server functionality.
A compressed installation file (zip) can be downloaded free of charge from the
ROTRONIC website at:
http://www.rotronic.ch/downloads/feuchte_software.php?language=ch-en 1
Activation requires a product key which can be requested by filling a form on the
ROTRONIC web site.
A trial product key will be sent to your e-mail address.
This must be entered in the registration form which appears when starting
HW4 for the first time.
After 30 days, the trial product key expires and
HW4 can no longer be started.
1
Web page subject to change.

Tiedonkeruulaite/dataloggeri
HygroLog NT
Advanced Humidity / Temperature Data Logger

HygroPalm
Kannettava kosteus-lämpötilamittari
The
HygroPalm uses the very latest in digital technology.
Three versions satisfy the needs of all users.
Each accepts a wide range of probes for maximum application flexibility.
The probes are interchangeable to virtually eliminate any downtime during calibration or maintenance.
The
HygroPalm offers a wide range of features, including calculation of various humidity parameters, precise software based probe calibration,
and on-site diagnostics / calibration of transmitters.
The optional docking station is used to recharge the battery and to connect to a PC for data logging * and instrument configuration.
* Not available with
HygroPalm 1
Mallit

Rotronic
HygroPalm 1
Kosteus/
lämpötilamittari
Key Features
• Portable indicator for relative humidity and temperature
• Display of dew-point or wet-bulb
• Indicator can be used to display transmitter readings
• 1-point probe adjustment directly from keypad

Rotronic
HygroPalm 2

Key Features
All the features of the
HygroPalm 1
+
Full range of psychrometric calculations
+ Multipoint probe calibration directly from keypad
+
RS232 PC interface for data logging
+ Second input for digital probe or connection to a transmitter
+
1-point adjustment of a transmitter against
HygroPalm probe
HygroPalm 3
Key Features
• All the features of the HygroPalm 2
+ Full transmitter calibration functions
+ Universal probe input for pressure, air-flow etc
+ Dynamic pressure compensation of calculated parameter
Using the HygroPalm as a calibrator for the
HygroFlex transmitters:
Each
HygroFlex Transmitter has a test connector, located at the bottom of the transmitter.
HygroPalm 1: remove the probe from the HygroPalm and replace it with cable #AC1621.
Connect the other end of the cable to the test connector of the transmitter.
You can now read the transmitter signals without interrupting its operation.
HygroPalm 2
and
HygroPalm 3: connect cable #AC1620 to the second probe input of the HygroPalm.
This lets you still use the probe connected to the first probe input.
In addition to reading the transmitter signals, you can also do a 1-point adjustment of the probe of the transmitter against the probe of the
HygroPalm
Anturivalikoima


Rotronic
Hygromer S1
S=Sword / miekka
Kirjapainojen suosikki kosteusmittari paperipinoista

|
 |
HygroClip S
for measurement in air, max. 85ºC , wire mesh filter
length: 100mm, Ø15mm |
|
 |
HygroClip SP05
for measurement in air ducts, max. 85ºC
tube length: 200mm,
Ø5mm
cable: 2m |
 |
HygroClip SC05
for measurement in tight spaces, max. 100ºC.
Ø5mm
, cable: 2m |
 |
HygroClip HK25 / HK40
air probe for measurement at high temperature
HK25: max. 150ºC. / HK40: max. 200ºC.
wire mesh filter
tube length: HK25: 250, / HK40: 400mm,
Ø15mm
cable: 2m |
 |
HygroClip HP28 insertion probe
for measurement of materials in bulk, max. 85ºC. sintered steel filter
tube length: 280,
Ø10mm
cable: 2m |
 |
HygroClip HS28 sword probe
for measurement of paper stacks/rolls, max. 85ºC
blade length: 280, w: 18mm,
th.: 4mm
cable: 2m |
| |
|
| |
|
Takaisin etusivulle
HW4-
ohjelma

HW4
Standard Edition: for single users.
Unlimited number of instruments (depends on capabilities of PC and available ports)
On-line display of the measured and calculated values (dew point or other) - limited to a single instrument at a time (instrument may have several probes).
Automatic retention of the most recent data in a temporary on-line buffer.
Logging of measured and calculated values to the PC (can be done simultaneously with local data logging).
Easy-to-read graphs and data tables.
Statistical data analysis: mean, standard deviation, minimum and maximum (off-line data only)
Data print-out (table or graph)
Automatic device/instrument recognition and identification
Device/instrument configuration
Adjustment / calibration of the
HygroClip
digital probes
Psychrometric Conversion Tool
Built-in security to protect against manipulation of recorded data
HW4
Professional Edition: meets the requirements of FDA 21CFR Part II / GAMP and allows multiple users, with either administrator or standard rights.
On each single port (RS-232, USB or TCP/IP),
HW4 Professional
can monitor up to 64 instruments connected together in a multi-dropped RS-485 network.
The number of such networks depends on the number of available ports.
All the functionality of
HW4
Standard
Edition
On-line display in a single graph of the data from multiple instruments and probes
Overlaying of several log files into a single graph
User Event Logging: automatically keeps track of user activity
Self Event Logging: automatically records eventual software problems to facilitate troubleshooting
Logger Event Logging: automatically records the data logger internal events and configuration changes.
Automatic creation of protocols detailing instrument configuration changes, log function programming and probe adjustments.
Password protected log-in
Indication of an alarm condition when displaying log file data
Indication on the PC of an alarm condition, printing of a report or sending an e-mail (MAPI or SMTP) 1
Automatic downloading and archiving on the PC of the files recorded locally by a data logger 1
Automatic synchronization of the networked devices with the PC time 1
Device protection against unauthorized configuration / programming changes 1
HW4 Professional Edition can be installed on a file server 1 for simultaneous access by several users (limited rights).
1 Availability of this feature depends on the HW4 software release and on the firmware release of some devices.
HW4
Requirements:
Computer/Operating System Requirements:
The following are the minimum values required to install and run
HW4
on a computer.
It is highly recommended to exceed these values.
Processor: Pentium II, 450 MHz
RAM: 128 MB
Available hard disk space: 50 MB |